INSTALLATION DATA | |
---|---|
Installation | Indoor or Outdoor |
Environment | Industrial, Marine |
Amb. Temperature Min/Max | -25°C (CS) and -40°C (LTCS) , storage only / 60°C * * |
OPERATING CONDITIONS | |
Fluids | Mineral and synthetic lubricating oil; Hydraulic oil; Diathermic oil; DFD-U and HFDR phosphate organic esters; Glycols; Heavy and Light Fuels |
Solid content | 0% * |
Viscosity range | between 1 and 400 cSt * * |
Speed | between 2900 and 3600 rpm * |
Rotation (shaft view) | Clockwise Counter clockwise on request |
TECHNICAL CHARACTERISTICS | |
Design available | SEIM STANDARD |
Flow rate | between 10 and 650 lpm (between 0.6 and 39 m3/h; between 2.7 and 171.8 GPM) * |
Suction pressure | between -0.5 and 10 barg (between -8 and 146 psi) * |
Delivery pressure | 100 barg (1451 psi) MAX * |
Operating temperature | between 0 and 100°C * |
Seal | Radial or mechanical |
Bearing | Radial ball |
Bearing lubrication | Self-lubricated external |
Drive | electric motor |
Construction shape | Horizontal or vertical |
IN/OUT | GAS - SAE |
Safety valve | Not available |
MATERIALS | |
Body/Flange | GG25. GGG40, Carbon steel * |
Set of 3 screws | Nitrided carbon steel * |
O-rings | Viton ® |
Painting | Not applicable |
(*) For different values contact SEIM |