INSTALLATION DATA | |
---|---|
Installation | Indoor or Outdoor |
Environment | Industrial |
Amb. Temperature Min/Max | -25°C (CS) and -40°C (LTCS) , storage only / 60°C * |
OPERATING CONDITIONS | |
Fluids | Fuels (HFO, LFO,MGO,DO,LSMGO); Mineral and synthetic lubricating oil; |
Solid content | 0% * |
Viscosity range | between 1.2 and 5000 cSt * * |
Speed | between 750 and 3600 rpm * * |
Rotation (shaft view) | Clockwise Counter clockwise on request |
TECHNICAL CHARACTERISTICS | |
Design available | STANDARD SEIM, BV MODE II, RINA |
Flow rate | between 3 and 41 lpm (between 0.18 and 2.46 m3/h; between 0.8 and 10.9 GPM) * |
Suction pressure | between -0.5 and 10 barg (between -8 and 146 psi) * |
Delivery pressure | 40 barg (581 psi) MAX * |
Operating temperature | between 0 and 150°C * |
Seal | Not available |
Bearing | Radial ball |
Bearing lubrication | Self-lubricated |
Drive | AC or DC motor |
Construction shape | Vertical submerged |
IN/OUT | Strainer or axial flange BSP |
Safety valve | Not available |
MATERIALS | |
Body/Flange | Aluminium * |
Screws | Carbon steel * |
(*) For different values contact SEIM |